ELECTROMEGNETIC FLOWMETER 6500 MAG PROBE 6510 (INSERTION TYPE)
INTRODUCTION
“ TORQUE” make Series 6500 is a new range of Bipolar Pulsed DC Insertion Type Electromagnetic Flow meter. It is suitable for pipes with nominal diameters of 100 mm & above. The Flow meter Is based on Faraday’s law of Electromagnetic Induction.
Series 6500 has excellent accuracy and flow range ability within its class. The meter is suitable for use on wide range of corrosive and aggressive range of conductive liquids.
SALIENT FEATURES
• Based on Faraday’s law of electromagnetic induction.
• Suitable for pipe sizes of diameters 100 mm & above
• With or without Integral Transmitter.
• Use of Isolating Ball Valve and Pressure Seal arrangement permits ease of mechanical Insertion and removal without disturbing the flow
• Absolute zero stability and noise elimination due to pulse D.C. excitation
• Measurement independent of liquid properties
• Optional inbuilt potentiometer provides full scale flow rate adjustments.
• Negligible pressure loss.
• Maintenance free design due to absence of any moving parts.
• Display of flow rate directly in user specified engineering units
APPLICATIONS
• Water Supply Networks
• Chemical and Process Industries
• Pharmaceutical Industry
• Waste- Water Management
• Sugar, Food and Beverages industries
• Effluent Treatment Plants
SPECIFICATION
Suitable for pipe sizes :DN 100 to DN 2000
Media Conductivity (Min) :10 µS / cm (Consult factory for 5 µS/cm)
Media pressure : Up to 15 15 kg / cm2
Media Temperature (PTFE) :0”-75º C
Ambient Temperature Range :0”-50º C
Material : Pipe : SS 316 (NON – Magnetic )
Wetted Parts : PTFE (Teflon) / SS 316
Electrode : SS/ Hostelry C / Ta / Ti / Pt
Weld in Socket with Flanges : Carbon steel
Connecting Flanges : Carbon steel
Transmitter : Cast aluminum (LM6), Epoxy painted
Mounting : Using a 2” Ball Valve Assembly
Power supply :110 / 240 V AC + 15 %, 50 Hz
Power consumption :20 VA
Cable Gland Entry : ½ “ NPT (F)
Analog Output :4-20 mA / DC / 0-20 mA DC
Pulsed Output (Optional) : Low Pulsed rate output 10 to 36000 pulses per hour
a) Output to drive directly external electromagnetic counter of 12/24 V DC @ 200 ma capacity OR
b) Open Collector output , High pulse rate output 0.5 KHz / 1 KHz/ (Open Collector Output)
Communication port (Optional) :RS – 232 / RS – 485 MODBUSRTU protocol
Maximum load Resistance : 1000
Response time :10 Second
Flow velocity Range :0.3 to 10 m/s)
Ingress Protection : IP – 65 for flow Transmitter and IP-68 for sensor Assembly
LED Display :4 Digit Indication for flow rate and 8 digit indication for
Totaliser programming from keyboard for engineeringUnits
Accuracy : K 2 % of span
For Flow Between 0 to 100% : Refer Error Diagram
Reference Conditions
Power Supply : Nominal
Ambient Temperature : 25º + 2ºc
Load Resistance : 500
Repeatability : + 0.2% of span
Effect of Ambient Temperature : Less than 0.2% per 10ºc
Effect of power supply : Less than 0.1% per 10% Voltage Variation
Effect of Load Resistance : Less than 0.1% of span
OPERATIONS
Electromagnetic Flowmeters are based on Faraday’s law of Electromagnetic Induction.
In a Electromagnetic Flowmeter, magnetic field is generated by a set of coils. As the conductive liquid passes through the electromagnetic field, an electric voltage is induced in the liquid, which is directly proportional its velocity. This Induced voltage is perpendicular to both the liquid flow direction and the electromagnetic field direction. The voltage sensed by the electrodes Is further processed by the transmitter to give standardized output signal or displayed In appropriate Engineering Units on LED Display.
The flux density of the electromagnetic field In a given Flow meter and the
distance between the electrodes are constant, therefore, the induced voltage is only a function or liquid velocity.